6HAL Power Generation Series

Yanmar Energy System’s 6HAL2 Series is a line of diesel generator units covering outputs from 140 kVA to 350 kVA. Thanks to their high reliability and thermal efficiency, 6HAL2 generators are widely used as emergency and continuous power sources in buildings, hospitals, department stores, hotels, and schools.
The engines used in the 6HAL2 series are known for their high reliability in Yanmar’s marine and general-industrial applications, earning the trust of professionals. Compared to gas turbines, they consume about half the fuel, allowing for about twice the operating hours on the same fuel supply, thereby achieving efficient and economical operation.

140 kVA– 263 kVA–
Series Stationary Power Generation
6HAL2 Series
Stationary Power Generation
6HAL2 Series
Stationary Power Generation
6HAL2 Series
Stationary Power Generation
6HAL2 Series
Model 6HAL2 6HAL2 6HAL2-T 6HAL2-T
Frequency 50 Hz 60 Hz 50 Hz 60 Hz
Generator Apparent Output (kVA) 140 160 200 250
Rated Output (kWe) 112 128 160 200
Type 3-Phase Brushless 3-Phase Brushless 3-Phase Brushless 3-Phase Brushless
Voltage (V) 6,600 (3,300 / 440 / 400 / 220 / 200) 6,600 (3,300 / 440 / 400 / 220 / 200) 6,600 (3,300 / 440 / 400 / 220 / 200) 6,600 (3,300 / 440 / 400 / 220 / 200)
No. of Poles (P) 4 4 4 4
Power Factor (%) 80 (lagging) 80 (lagging) 80 (lagging) 80 (lagging)
Diesel Engine Rated Output (kW) 128 150 180 224
Type Vertical, Water-cooled, 4-stroke Diesel Vertical, Water-cooled, 4-stroke Diesel Vertical, Water-cooled, 4-stroke Diesel Vertical, Water-cooled, 4-stroke Diesel
No. of Cylinders 6 6 6 6
Bore × Stroke (mm) 130 × 165 130 × 165 130 × 165 130 × 165
Rated Speed (min-1) 1,500 1,800 1,500 1,800
Total Weight (Gen. Set) (kg) 2,900 2,900 3,000 3,000
Series Stationary Power Generation
6HAL2 Series
Stationary Power Generation
6HAL2 Series
Stationary Power Generation
6HAL2 Series
Stationary Power Generation
6HAL2 Series
Model 6HAL2-HT 6HAL2-HT 6HAL2-DT 6HAL2-DT
Frequency 50 Hz 60 Hz 50 Hz 60 Hz
Generator Apparent Output (kVA) 263 313 313 350
Rated Output (kWe) 210 250 250 280
Type 3-Phase Brushless 3-Phase Brushless 3-Phase Brushless 3-Phase Brushless
Voltage (V) 6,600 (3,300 / 440 / 400 / 220 / 200) 6,600 (3,300 / 440 / 400 / 220 / 200) 6,600 (3,300 / 440 / 400 / 220 / 200) 6,600 (3,300 / 440 / 400 / 220 / 200)
No. of Poles (P) 4 4 4 4
Power Factor (%) 80 (lagging) 80 (lagging) 80 (lagging) 80 (lagging)
Diesel Engine Rated Output (kW) 234 278 278 320
Type Vertical, Water-cooled, 4-stroke Diesel Vertical, Water-cooled, 4-stroke Diesel Vertical, Water-cooled, 4-stroke Diesel Vertical, Water-cooled, 4-stroke Diesel
No. of Cylinders 6 6 6 6
Bore × Stroke (mm) 130 × 165 130 × 165 130 × 165 130 × 165
Rated Speed (min-1) 1,500 1,800 1,500 1,800
Total Weight (Gen. Set) (kg) 3,200 3,200 3,300 3,300
  • The rated output is based on the “Prime Power” rating.
  • The rated output of each generator is based on the bylaw of generator efficiency in JEM1355.
  • The dry weight value is for reference only. The value can vary depending on the generator manufacturer, equipment specifications, accessories, etc.
  • Specifications are subject to change without notice for incorporation of improvements.
  • Dimensions (Unit: mm)

    6HAL2 Series Dimensions
    Series Stationary Power Generation
    6HAL2 Series
    Stationary Power Generation
    6HAL2 Series
    Stationary Power Generation
    6HAL2 Series
    Stationary Power Generation
    6HAL2 Series
    Model 6HAL2 6HAL2-T 6HAL2-HT 6HAL2-DT
    Length A 3,000 3,100 3,200 3,350
    B 1,050 1,050 1,050 1,050
    C 1,400 1,500 1,500 1,500
    D 2,100 2,200 2,300 2,450
    E 900 900 900 900
    F 650 650 650 650
    G 1,450 1,450 1,450 1,450
  • The dry weight value is for reference only. The value can vary depending on the generator manufacturer, equipment specifications, accessories, etc.
  • Download Form

    The engines used in the 6HAL2 series are designed for versatility, suitable for various applications, including marine and general-industrial sectors. They feature a high-durability design that withstands harsh environments, ensuring stable operation as emergency generators. This allows for safe use during disasters and emergencies.
    Backed by a robust design proven through experience, these generators deliver reliable performance during long-term operation. They provide constant peace of mind as backup power sources for facilities, whether during normal or emergency situations.

    The engines in the 6HAL2 series not only possess high output and fuel efficiency but are also designed with a focus on reducing environmental impact. They comply with emission regulations, and their low fuel consumption enables operation with reduced CO2 and harmful substance emissions.
    While meeting the performance requirements for emergency power supply, the 6HAL2 series also contributes to a sustainable society, making it a balanced generator series that considers both efficiency and environmental responsibility.

    View All Articles
    Hyatt Place Hotel Portland, Maine
    Cogeneration Commercial Leisure
    Pike Road School
    GHP Education Public Medical
    Tochiku Hospital (GHP / GHP Chiller / Micro-Cogeneration)
    GHP Education Public Medical
    View All Cases

    6HAL Power Generation Series Inquiries and Support